In collaboration with Payame Noor University and the Iranian Society of Instrumentation and Control Engineers

Document Type : Research Article

Authors

Department of Electrical Engineering, Faculty of Engineering, Yazd University, Yazd, Iran

Abstract

This paper presents a simulation-based predictive control framework for reference tracking in a nonlinear quadruple-tank system. First, a nonlinear parameter identification approach is employed to estimate the unknown pump and valve parameters. The maximum relative parameter error obtained using the interior-point method with the ℓ1-norm formulation is 0.57%. The identified model is then used to obtain the step-response coefficients required for the two-input, two-output dynamic matrix control (DMC) formulation. The DMC controller is implemented within a receding-horizon framework, and analytical and sequential quadratic programming (SQP) approaches are considered for solving the associated optimization problem. In the investigated simulations, both approaches achieved similar reference-tracking behavior, while only the SQP method explicitly enforces the pump-voltage and voltage-increment constraints. Furthermore, a dynamic reference governor (DRG) is integrated into the control framework to modify the desired reference when necessary to accommodate system constraints. The DRG jointly optimizes control input increments and reference adjustment variables. The DMC step-response model is used to predict the lower-tank outputs, while the nonlinear plant model is used to evaluate the upper-tank state constraints over a five-step prediction horizon with a sampling time of 10 s. Simulation results demonstrate that the DRG adjusts the reference when necessary to satisfy the imposed nonlinear state constraints and allows the governed reference to approach the desired reference when feasible. These results illustrate the potential of integrating a nonlinear model-based reference governor with DMC for constrained reference tracking.

Highlights

  1. Nonlinear identification estimates tank pump and valve parameters with 0.57% maximum relative error
  2. Step-response model from the identified plant drives a two-input, two-output DMC controller
  3. SQP-based DMC enforces pump-voltage and voltage-increment limits that the analytical solution violates
  4. A dynamic reference governor jointly optimizes control increments and reference adjustments within DMC
  5. DRG satisfies nonlinear upper-tank level constraints and approaches the desired reference when feasible

Keywords

Main Subjects

[1] Aghaei, S., Daeichian, A., Puig, V. (2020). “Hierarchical decentralized reference governor using dynamic constraint tightening for constrained cascade systems”. Journal of the Franklin Institute, 357(17), 12495–12517. https://doi.org/10.1016/j.jfranklin. 2020.09.040
[2] Aghaei, S., Sheikholeslam, F., Farina, M., Scattolini, R. (2013). “An MPC-based reference governor approach for offset-free control of constrained linear systems”. International Journal of Control, 86(9), 1534–1539. https://doi.org/10.1080/00207179.2013. 789142
[3] Aghaei, S., Zakeri, Y., Sheikholeslam, F. (2008). “Offset-free control of constrained linear systems using model predictive control”. IEEE International Symposium on Industrial Electronics, Cambridge, UK, 973–979. https://doi.org/10.1109/ISIE.2008. 4677027
[4] Alvarado, I., Limón, D., De La Peña, D. M., Maestre, J. M., Ridao, M. A., Scheu, H., Espinosa, J. (2011). “A comparative analysis of distributed MPC techniques applied to the HD-MPC four-tank benchmark”. Journal of Process Control, 21(5), 800–815. https://doi.org/10.1016/j.jprocont.2011.03.003
[5] Boikov, I. V., Krivulin, N. P. (2018). “Identification of parameters of nonlinear dynamical systems simulated by Volterra polynomials”. Journal of Applied and Industrial Mathematics, 12(2), 220–233. https://doi.org/10.1134/S1990478918020035
[6] Bustos-Pulluquitin, S., Caiza, G., Llumitasig-Galarza, M., Castro-Mayorga, M., Sánchez Benítez, C., García, M. V. (2023). “Constrained dynamic matrix control under International Electrotechnical Commission standard 61499 and the Open Platform Communications Unified Architecture”. Sensors, 23(15), 6919. https://doi.org/10.3390/ s23156919
[7] Camacho, E. F., Bordons, C. (2007). “Model predictive control”. Springer London. https: //doi.org/10.1007/978-0-85729-398-5
[8] Casavola, A., Famularo, D., Franzè, G., Furfaro, A. (2010). “A fault-tolerant real-time supervisory scheme for an interconnected four-tank system”. Proceedings of the 2010 American Control Conference, 6210–6215. https://doi.org/10.1109/ACC.2010. 5531619
[9] Chauhan, S., Singh, B., Singh, M. (2021). “Modified ant colony optimization based PID controller design for coupled tank system”. Engineering Research Express, 3(4), 045005. https://doi.org/10.1088/2631-8695/ac2bf3
[10] Chubich, V. M., Kulabukhova, S. O. (2021). “Robust parametric identification procedure for stochastic nonlinear continuous-discrete systems”. Journal of Applied and Industrial Mathematics, 15(3), 384–392. https://doi.org/10.1134/S1990478921030030
[11]  Cutler, C. R., Ramaker, B. L. (1980). “Dynamic matrix control—A computer control algorithm”. In Proceedings of the 1980 Joint Automatic Control Conference, Paper WP5- B, pp. WP5-B1–WP5-B6, San Francisco, CA, USA. 
[12] Dai, L., Astrom, K. J. (1999). “Dynamic matrix control of a quadruple-tank process”. IFAC Proceedings Volumes, 32(2), 6902–6907. https://doi.org/10.1016/ S1474-6670(17)57178-5
[13] Denisov, V. I., Timofeeva, A. Y., Khailenko, E. A., Buzmakova, O. I. (2014). “Robust estimation of nonlinear structural models”. Journal of Applied and Industrial Mathematics, 8(1), 28–39. https://doi.org/10.1134/S1990478914010049
[14] Figura, M., Su, L., Inoue, M., Gupta, V. (2024). “Instant distributed MPC with reference governor”. International Journal of Control, 97(4), 662–672. https://doi.org/10.1080/00207179.2023.2164868
[15] Garone, E., Di Cairano, S., Kolmanovsky, I. (2017). “Reference and command governors for systems with constraints: A survey on theory and applications”. Automatica, 75, 306– 328. https://doi.org/10.1016/j.automatica.2016.08.013
[16] Hatamian, R., Samareh Hashemi, S. A. (2025). “A hybrid numerical approach for solving nonlinear optimal control problems”. Control and Optimization in Applied Mathematics, 10(1), 125–138. https://doi.org/10.30473/coam.2025.72875.1273
[17] Hedengren, J. D., Shishavan, R. A., Powell, K. M., Edgar, T. F. (2014). “Nonlinear modeling, estimation and predictive control in APMonitor”. Computers & Chemical Engineering, 70, 133–148. https://doi.org/10.1016/j.compchemeng.2014.04.013
[18] Johansson, K. H. (2000). “The quadruple-tank process: A multivariable laboratory process with an adjustable zero”. IEEE Transactions on Control Systems Technology, 8(3), 456–465. https://doi.org/10.1109/87.845876
[19] Kalabić, U. V., Buckland, J. H., Cooper, S. L., Wait, S. K., Kolmanovsky, I. V. (2016). “Reference governors for enforcing compressor surge constraints”. IEEE Transactions on Control Systems Technology, 24(5), 1729–1739. https://doi.org/10.1109/TCST. 2015.2510334
[20] Limon, D., Alvarado, I., Alamo, T., Camacho, E. F. (2008). “MPC for tracking piecewise constant references for constrained linear systems”. Automatica, 44(9), 2382–2387. https://doi.org/10.1016/j.automatica.2008.01.023
[21] Liu, L., Tian, S., Xue, D., Zhang, T., Chen, Y., Zhang, S. (2019). “A review of industrial MIMO decoupling control”. International Journal of Control, Automation and Systems, 17(5), 1246–1254. https://doi.org/10.1007/s12555-018-0367-4
[22] Nocedal, J., Wright, S. J. (2006). “Numerical optimization”. Springer. https://doi. org/10.1007/978-0-387-40065-5
[23] Pachare, A., Thosar, A. (2021). “Level control of quadruple tank system with feedback linearization”. Smart Sensors, Measurements and Instrumentation: Select Proceedings of CISCON 2020, 455–469. Springer, Singapore. https://doi.org/10.1007/ 978-981-16-0336-5_38
[24] Rigatos, G., Cuccurullo, G., Siano, P., Busawon, K., Abbaszadeh, M. (2020). “Nonlinear optimal control for the quadruple water tank system”. AIP Conference Proceedings, 2293(1), 310005. https://doi.org/10.1063/5.0026532
[25] Schwenzer, M., Ay, M., Bergs, T., Abel, D. (2021). “Review on model predictive control: An engineering perspective”. The International Journal of Advanced Manufacturing Technology, 117(5), 1327–1349. https://doi.org/10.1007/s00170-021-07682-3
[26] Shi, Y., Zhang, Z., Chang, H., Xie, L., Su, H. (2023). “Pseudo feedforward dynamic matrix control algorithm for desired closed-loop performance in MPC systems”. Journal of Process Control, 123, 37–49. https://doi.org/10.1016/j.jprocont.2023.01.008
[27] Ullah, N., Mohammad, A. (2022). “A simulation approach for closed-loop control of coupled four tank system”. International Journal of Modeling, Simulation, and Scientific Computing, 13(4), 2250029. https://doi.org/10.1142/S1793962322500295
[28] Van Overschee, P., De Moor, B. (1994). “N4SID: Subspace algorithms for the identification of combined deterministic-stochastic systems”. Automatica, 30(1), 75–93. https://doi.org/10.1016/0005-1098(94)90230-5
[29] Zhang, Y., Wang, P., Yu, L., Li, N. (2025). “Adaptive tuning of dynamic matrix control for uncertain industrial systems with deep reinforcement learning”. IEEE Transactions on Automation Science and Engineering, 22, 8695–8708. https://doi.org/10.1109/ TASE.2024.3487878